Sign In | Join Free | My burrillandco.com
Home > Rat ELISA Kit >

Laboratory Research Use Rat ELISA Kit Pre - Coated with Rat GHRL Antibody

Shanghai Korain Biotech Co., Ltd
Contact Now
    Buy cheap Laboratory Research Use Rat ELISA Kit Pre - Coated with Rat GHRL Antibody from wholesalers
     
    Buy cheap Laboratory Research Use Rat ELISA Kit Pre - Coated with Rat GHRL Antibody from wholesalers
    • Buy cheap Laboratory Research Use Rat ELISA Kit Pre - Coated with Rat GHRL Antibody from wholesalers

    Laboratory Research Use Rat ELISA Kit Pre - Coated with Rat GHRL Antibody

    Ask Lasest Price
    Brand Name : BT Lab
    Model Number : Cat.No E0896Ra
    Certification : CE, ISO9001:2005, MSDS
    Price : Negotiation
    Supply Ability : Western Union, T/T
    Delivery Time : 1-3 business days, bulk order within one week
    • Product Details
    • Company Profile

    Laboratory Research Use Rat ELISA Kit Pre - Coated with Rat GHRL Antibody

    Specificity and sensitivity Rat Ghrelin ELISA Kit 96 wells


    Cat.No E0896Ra

    Standard Curve Range: 40ng/L - 12000ng/L

    Sensitivity: 20.56ng/L

    Size: 96 wells

    Storage: Store the reagents at 2-8°C. For over 6-month storage refer to the expiration date keep it at -20°C. Avoid repeated thaw cycles. If individual reagents are opened it is recommended that the kit be used within 1 month.

    * This product is for research use only, not for use in diagnosis procedures. It’s highly recommend to read this instruction entirely before use.


    Intended Use

    This sandwich kit is for the accurate quantitative detection of Rat Ghrelin (also known as GHRL) in serum, plasma, cell culture supernates, cell lysates, tissue homogenates.


    Assay Principle

    This kit is an Enzyme-Linked Immunosorbent Assay (ELISA). The plate has been pre-coated with Rat GHRL antibody. GHRL present in the sample is added and binds to antibodies coated on the wells. And then biotinylated Rat GHRL Antibody is added and binds to GHRL in the sample. Then Streptavidin-HRP is added and binds to the Biotinylated GHRL antibody. After incubation unbound Streptavidin-HRP is washed away during a washing step. Substrate solution is then added and color develops in proportion to the amount of Rat GHRL. The reaction is terminated by addition of acidic stop solution and absorbance is measured at 450 nm.


    Reagent Provided

    ComponentsQuantity
    Standard Solution (12800ng/L)0.5ml x1
    Pre-coated ELISA Plate12 * 8 well strips x1
    Standard Diluent3ml x1
    Streptavidin-HRP6ml x1
    Stop Solution6ml x1
    Substrate Solution A6ml x1
    Substrate Solution B6ml x1
    Wash Buffer Concentrate (30x)20ml x1
    Biotinylated Rat GHRL Antibody1ml x1
    User Instruction1
    Plate Sealer2 pics
    Zipper bag1 pic

    Reagent Preparation

    All reagents should be brought to room temperature before use.

    Standard Reconstitute the 120μl of the standard (12800ng/L) with 120μl of standard diluent to generate a 6400ng/L standard stock solution. Allow the standard to sit for 15 mins with gentle agitation prior to making dilutions. Prepare duplicate standard points by serially diluting the standard stock solution (6400ng/L) 1:2 with standard diluent to produce 3200ng/L, 1600ng/L, 800ng/L and 400ng/L solutions. Standard diluent serves as the zero standard(0 ng/L). Any remaining solution should be frozen at -20°C and used within one month. Dilution of standard solutions suggested are as follows:


    6400ng/LStandard No.5120μl Original Standard + 120μl Standard Diluent
    3200ng/LStandard No.4120μl Standard No.5 + 120μl Standard Diluent
    1600ng/LStandard No.3120μl Standard No.4 + 120μl Standard Diluent
    800ng/LStandard No.2120μl Standard No.3 + 120μl Standard Diluent
    400ng/LStandard No.1120μl Standard No.2 + 120μl Standard Diluent

    Standard ConcentrationStandard No.5Standard No.4Standard No.3Standard No.2Standard No.1
    12800ng/L6400ng/L3200ng/L1600ng/L800ng/L400ng/L

    Wash Buffer Dilute 20ml of Wash Buffer Concentrate 30x into deionized or distilled water to yield 500 ml of 1x Wash Buffer. If crystals have formed in the concentrate, mix gently until the crystals have completely dissolved.


    Calculation of Result

    Construct a standard curve by plotting the average OD for each standard on the vertical (Y) axis against the concentration on the horizontal (X) axis and draw a best fit curve through the points on the graph. These calculations can be best performed with computer-based curve-fitting software and the best fit line can be determined by regression analysis.


    References

    Ariyasu H., Takaya K., Hosoda H., Iwakura H., Ebihara K., Mori K., Ogawa Y., Hosoda K., Akamizu T., Kojima M., Kangawa K., Nakao K.
    Endocrinology 143:3341-3350(2002)

    Quality Laboratory Research Use Rat ELISA Kit Pre - Coated with Rat GHRL Antibody for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shanghai Korain Biotech Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)