Sign In | Join Free | My burrillandco.com
Home > Rat ELISA Kit >

IGF1 Rat ELISA Kit , 1.55ng/ml Sensitivity Enzyme Linked Immunosorbent Assay Kit

Shanghai Korain Biotech Co., Ltd
Contact Now
    Buy cheap IGF1 Rat ELISA Kit , 1.55ng/ml Sensitivity Enzyme Linked Immunosorbent Assay Kit from wholesalers
     
    Buy cheap IGF1 Rat ELISA Kit , 1.55ng/ml Sensitivity Enzyme Linked Immunosorbent Assay Kit from wholesalers
    • Buy cheap IGF1 Rat ELISA Kit , 1.55ng/ml Sensitivity Enzyme Linked Immunosorbent Assay Kit from wholesalers

    IGF1 Rat ELISA Kit , 1.55ng/ml Sensitivity Enzyme Linked Immunosorbent Assay Kit

    Ask Lasest Price
    Brand Name : BT Lab
    Model Number : Cat.No E0709Ra
    Certification : CE, ISO9001:2005, MSDS
    Price : Negotiation
    Supply Ability : Western Union, T/T
    Delivery Time : 1-3 business days, bulk order within one week
    • Product Details
    • Company Profile

    IGF1 Rat ELISA Kit , 1.55ng/ml Sensitivity Enzyme Linked Immunosorbent Assay Kit

    96 wells Rat High sensitivity IGF1 ELISA Kit


    Cat.No E0709Ra

    Standard Curve Range: 3ng/ml - 900ng/ml

    Sensitivity: 1.55ng/ml

    Size: 96 wells

    Storage: Store the reagents at 2-8°C. For over 6-month storage refer to the expiration date keep it at -20°C. Avoid repeated thaw cycles. If individual reagents are opened it is recommended that the kit be used within 1 month.

    * This product is for research use only, not for use in diagnosis procedures. It’s highly recommend to read this instruction entirely before use.


    Reagent Provided

    ComponentsQuantity
    Standard Solution (960ng/ml)0.5ml x1
    Pre-coated ELISA Plate12 * 8 well strips x1
    Standard Diluent3ml x1
    Streptavidin-HRP6ml x1
    Stop Solution6ml x1
    Substrate Solution A6ml x1
    Substrate Solution B6ml x1
    Wash Buffer Concentrate (30x)20ml x1
    Biotinylated Rat IGF-1 Antibody1ml x1
    User Instruction1
    Plate Sealer2 pics
    Zipper bag1 pic

    Material Required But Not Supplied

    • 37°C±0.5°C incubator
    • Absorbent paper
    • Precision pipettes and disposable pipette tips
    • Clean tubes
    • Deionized or distilled water
    • Microplate reader with 450 ± 10nm wavelength filter

    Specimen Collection

    Serum Allow serum to clot for 10-20 minutes at room temperature. Centrifuge at 2000-3000 RPM for 20 minutes.


    Plasma Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples for 15 minutes at 2000-3000 RPM at 2 - 8°C within 30 minutes of collection.


    Urine Collect by sterile tube. Centrifuge at 2000-3000 RPM for approximately 20 minutes. When collecting pleuroperitoneal fluid and cerebrospinal fluid, please follow the procedures above-mentioned.


    Cell Culture Supernatant Collect by sterile tubes when examining secrete components. Centrifuge at 2000-3000 RPM for approximately 20 minutes. Collect the supernatants carefully. When examining the components within the cell, use PBS (pH 7.2-7.4) to dilute cell suspension to the cell concentration of approximately 1 million/ml. Damage cells through repeated freeze-thaw cycles to let out the inside components. Centrifuge at 2000-3000 RPM for approximately 20 minutes.


    Tissue Rinse tissues in PBS (pH 7.4) to remove excess blood thoroughly and weigh before homogenization. Mince tissues and homogenize them in PBS (pH7.4) with a glass homogenizer on ice. Thaw at 2-8°C or freeze at -20°C. Centrifuge at 2000-3000 RPM for approximately 20 minutes.


    Note

    • Sample concentrations should be predicted before being used in the assay. If the sample concentration is not within the range of the standard curve, users must contact us to determine the optimal sample for their particular experiments.

    • Samples to be used within 5 days should be stored at 2-8°C. Samples should be aliquoted or must be stored at -20°C within 1 month or -80°C within 6 months. Avoid repeated freeze thaw cycles.

    • Samples should be brought to room temperature before starting the assay.

    • Centrifuge to collect sample before use.

    • Samples containing NaN3 can’t be tested as it inhibits the activity of Horse Radish Peroxidase (HRP).

    • Collect the supernatants carefully. When sediments occurred during storage, centrifugation should be performed again.

    * Sample can't be diluted with this kit. Owing to the the material we use to prepare the kit, the sample matrix interference may falsely depress the specificity and accuracy of the assay.


    Calculation of Result

    Construct a standard curve by plotting the average OD for each standard on the vertical (Y) axis against the concentration on the horizontal (X) axis and draw a best fit curve through the points on the graph. These calculations can be best performed with computer-based curve-fitting software and the best fit line can be determined by regression analysis.


    References

    Pellizas C.G., del Mar Montesinos M., Masini-Repiso A.M., Torres A.I., Coleoni A.H.
    Thyroid 12:1071-1078(2002)

    Quality IGF1 Rat ELISA Kit , 1.55ng/ml Sensitivity Enzyme Linked Immunosorbent Assay Kit for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shanghai Korain Biotech Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)